ITP–Test Pattern
Displays a test pattern.
Commands
Command
Description
ITP <index>
Enables or disables test patterns.
This command is only available if video electronics are
on.
ITP+FREQ <value>
Sets the frequency at which the internal test patterns
are displayed.
This command is only available if video electronics are
on.
ITP+GREY <grey
Defines the shade of grey for the Flat Grey test pattern.
level>
This command is only available if video electronics are
on.
ITP+RMPM <speed>
Defines the motion speed used for the Horizontal Ramp,
Vertical Ramp, and Diagonal Ramp test patterns.
This command is only available if video electronics are
on.
ITP+RMPS <slope>
Defines the slope used for the Horizontal Ramp, Vertical
Ramp, and Diagonal Ramp test patterns.
Boxer 4K Serial API Commands Technical Reference
020-101697-05 Rev. 1 (07-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Serial API commands
Values
0 = Off
1 = Grid
2 = Grey Scale 16
3 = Flat White
4 = Flat Grey
5 = Flat Black
6 = Checker
7 = 17 Point
8 = Edge Blend
9 = Color Bars
10 = Multi Color
11 = RGBW Ramp
12 = Horizontal Ramp
13 = Vertical Ramp
14 = Diagonal Ramp
15 = Square Grid
16 = Diagonal Grid
17 = Maximum Activity
18 = Prism/Convergence
21 = Boresight
22 = Convergence
23 = Integrator Rod
25 = Resolution Demo
24 to 500
60 (Default)
0 to 4095
2048 (Default)
0 to 100
0 (Default)
1 to 5
1 (Default)