Pumps - ProMinent DULCOMETER D1Cb Series Instructions For Assembly And Use

Hide thumbs Also See for DULCOMETER D1Cb Series:
Table of Contents

Advertisement

9.1 Pumps

CAUTION!
Observe the operating manual for the pump
Possibility of damage to the pump. Faults in the process.
The pump must be set to "External Control" operating mode
Observe the maximum stroke rate for the pump
Possibly switch off any stroke memories in the pump controller
The maximum stoke rate for the pump can be found in the operating manual for the pump
Setting a stroke rate on the controller, which is higher than the actual possible maximum
stroke rate of the pump, can lead to hazardous operating conditions
NOTICE!
Maximum pump frequency
The pumps are activated in accordance with the actuating variable up to the respective maximum
frequency of the pump.
Only with pumps for control
pumps
setting ?
Fig. 46: Pumps
Factory setting
Strokes
180
Critical when setting the stroke rate is the flow rate of the pump in relation to the respective
process. Observe the maximum pump frequency
Operating Menus Independent of Measured Variables
control
pump 1
pump 2
Possible values
Increment
Lower value
1
0
dosing pump max.
pump 1:
180
pump 2:
180
pulse/minute
Upper value
Remarks
500
A0021_GB
95

Advertisement

Table of Contents
loading

Table of Contents