10.2 Summary of Error Texts

Error
Error text
Actuating
Check
variable
sensor
exceeds
control time
of reading
Upper and
Input
lower limits
of signal
breached
(only with
mA input)
Calibration
Compensa‐
sensor has
tion defec‐
a fault
tive
Correction
Temp. input
variable -
upper/lower
signal
breached
Limit value
Limit value
transgres‐
1
sion after
Limit value
control time
2
of limit value
114
Symbol
Effect on
actuating
variable
Basic load
Basic load
Basic load
Basic load
Stop or
basic load
Effect on
Alarm with
control
acknowl‐
edgement
Stop
Yes
Stop
Yes
Stop
No
Stop
Yes
Stop
Yes
Yes
Remarks
Function
can be
switched off
Signal <3.0
±0.2 mA or
>23 ±0.2
mA
Metering
continues
with fault
with
unsteady
readings
Pt100
signal >138.
5 Ω signal,
<100 Ω
Pt1000
signal
>1385 Ω
signal, <
1000 Ω
The last
valid value
will be
reused
Function
can be
switched off