Power Requirements; Power Supply Inputs; Power Supply Consumption; Fuse Replacement - NEC ElectraElite 48 System Hardware Manual

Table of Contents

Advertisement

Electra Elite
System Hardware Manual
4.3

Power Requirements

4.3.1

Power Supply Inputs

The AC input requirements for the Electra Elite 48 system
are listed below.
AC Input (P64-U10 PSU)
4.3.2

Power Supply Consumption

The power consumption for the Electra Elite 48 system is
listed in
KSU
B48-U10 KSU
4.3.3

Fuse Replacement

When replacing fuses, refer to the specifications in
2-9 Fuse
Fuse
Unit
Number
P64-U10
F1
PSU
P64-U10
F101
PSU
All fuses are normal blown glass tube.
117 Vac ± 10%
60 Hz ± 10%
Single Phase
2.5A circuit
A dedicated outlet, separately fused and grounded
Table 2-8 Power
Consumption.

Table 2-8 Power Consumption

Maximum
RMS
Current
2.5 A
Replacement.

Table 2-9 Fuse Replacement

Specifications
125V, 6.0A
250v, 10A
Watts Used
Watts Used
(Idle)
(Maximum)
90
230
Description
Dimensions
AC Input
1/4" x 1-1/4"
Battery Input
1/4" x 1-1/4
Issue 6
Table
2 - 9