Notes:
When recording in handsfree (half-duplex) mode using the built-in speakerphone, the record warning
tone may not be audible to the far-end party.
The transmit recording level is lower than the receiving voice level for intercom calls; the transmit
recording level for CO calls is normal.
Depending on the recording device(s), separate cables may be required for the warning tone and
speech path. In this case, connect the warning tone cables to input terminals T1 and T2 on the AD(A)-R
Unit. (T3 and T4 are used as the tape recorder input.)
When remote control of the recorder is necessary, the record start/stop control is provided by
connecting to T5 (or T7) and T6 on the ADA-U Unit.
specifications of the recorder.)
When a warning Tone is provided from the recording equipment, it should be input via T3 and T4 on
AD(A)-R Unit. (Do not use T1 and T2 to input Beep Tone.)
Conversations cannot be recorded from terminals connected to an AP(R)-R Unit.
8 - 40
AD(A)-R
Table 8-2
Cable Connections (Continued)
Installing Electra Elite IPK and D
(Connecting to T5 or T7 is determined by the