<cartridge address> - specifies the location of the cartridge to export in library, rail,
■
column, side, row format. The specified cartridge must be in a system slot and
must be either a cleaning or diagnostic cartridge.
Example:
SL3000> cleaning export 1,1,5,2,0 1,4,-12,1,12
requestId
requestId 9601
Address
1.4.-12.1.12
Success
Cartridge Exported
Volume Label CLN002CU
Message CAP open(ing). Remove cartridges, then close CAP.Use CONTINUE cmd to
proceed...
Done
Failure Count 0
Success Count 1
COMPLETED
cleaning threshold list
Displays a list of cleaning cartridge types and their warning thresholds. Each cleaning
cartridge type has 4 attributes:
Index - cleaning cartridge type used by the "cleaning threshold set" command
■
Media type - the type of cleaning cartridge used
■
Maximum usage count - recommended max usage by tape manufacturer
■
Warning threshold value - user-defined threshold that determines when a
■
warning status is set for a cleaning cartridge once its usage count reaches that
threshold.
Example:
SL3000> cleaning threshold list
requestId
requestId 15001
Attributes
Object
Index
Media Type
Recommend Max Usage 100
Warning Threshold
Attributes
Object
Index
Media Type
Recommend Max Usage 50
Warning Threshold
cleaning threshold set <warning threshold value> <list index number>
Sets a warning threshold value for a particular cleaning cartridge type.
<warning threshold value> - can be any positive integer up to 1000. A value of 0
■
indicates no warning threshold.
<list index number> - cleaning cartridge type as specified by the index number from
■
the table listing of the "cleaning threshold list" command.
Example:
SL3000> cleaning threshold set 55 11
requestId
requestId 15101
Attributes
1
SgtUltrium1_Cleaning
0
3
T10000_Cleaning
0
Command Line Interface Reference A-5
cleaning
Need help?