Turning Off the Library
■
Turning On the Library
■
Entering the Library
■
Opening the AEM Access Door
■
Manually Cleaning a Drive
■
Manually Mounting and Dismounting a Cartridge
■
See Also
"Troubleshooting"
■
Turning Off the Library
Ensure all library requests have completed.
1.
Take all library drives offline (see
2.
Take the library offline (see
3.
Open the rear doors of the Base Module (and DEM if present).
4.
Turn off the power enable switches.
5.
If necessary, turn off the circuit breakers on the PDUs.
6.
Turning On the Library
Open the rear doors of the Base Module (and DEM if present).
1.
If necessary, turn on the circuit breakers on the PDUs.
2.
Turn on the power enable switches.
3.
The library goes through the initialization sequence. If someone opened the access
doors while the library was off, the library performs a full audit.
on page 17-1
Caution:
If you shut off power to the library without performing the
following procedure, you risk possible equipment damage, cartridge
damage, and loss of data.
Servicing the Library
18
"Taking a Device Offline"
"Taking the Library Offline"
18
on page 16-2).
on page 16-1).
Servicing the Library 18-1