GE Power Quality Meter Series Instruction Manual page 208

Table of Contents

Advertisement

7.3 MODBUS MEMORY MAP
Table 7–10: PQM MEMORY MAP (Sheet 28 of 40)
GROUP
ADDR
(HEX)
CLEAR DATA
103D
continued
103E
103F
1040
1041
1042
1043
DNP
1044
1045
1046
TARIFF
1047
1048
1049
104A
104B
104C
104D
104E
104F
CURRENT
1050
/VOLTAGE
1051
CONFIG.
1052
1053
1054
1055
1056
1057
1058
1059
7
to
105F
ANALOG
1060
OUTPUT 1
1061
1062
1063
1064
1065
1066
1067
ANALOG
1068
OUTPUT 2
1069
106A
106B
106C
Notes:
* Data type depends on the Command Operation Code.
*** Maximum Setpoint value represents "OFF".
***** Maximum Setpoint value represents "UNLIMITED".
7-42
DESCRIPTION
Clear Max THD Values
Clear Pulse Input Values
Clear Event Record
Clear All Demand Values
Clear Frequency Values
Reserved
Reserved
DNP Port
DNP Slave Address
DNP Turnaround Time
Tariff Period 1 Start Time
Tariff Period 1 Cost per MWh
Tariff Period 2 Start Time
Tariff Period 2 Cost per MWh
Tariff Period 3 Start Time
Tariff Period 3 Cost per MWh
Reserved
Reserved
Reserved
Phase CT Primary
Neutral Current Sensing
Neutral CT Primary
VT Wiring
VT Ratio
VT Nominal Secondary Voltage
Nominal Direct Input Voltage
Nominal Frequency
CT Wiring
Reserved
Reserved
Analog Output 1 Main Type
Analog Output 1 Main Min Value
Analog Output 1 Main Max Value
Analog Output 1 Alternate Type
Analog Output 1 Alternate Min Value
Analog Output 1 Alternate Max Value
Reserved
Analog Output 1 Serial Value
Analog Output 2 Main Type
Analog Output 2 Main Min Value
Analog Output 2 Main Max Value
Analog Output 2 Alternate Type
Analog Output 2 Alternate Min Value
PQM Power Quality Meter
7 MODBUS COMMUNICATIONS
RANGE
STEP
UNITS and
VALUE
SCALE
0 to 1
1
---
0 to 1
1
---
0 to 1
1
---
0 to 1
1
---
0 to 1
1
---
0 to 3
1
---
0 to 255
1
---
0 to 100
10
ms
0 to 1439
1
minutes
¢ × 0.01
1 to 50000
1
0 to 1439
1
minutes
¢ × 0.01
1 to 50000
1
0 to 1439
1
minutes
¢ × 0.01
1 to 50000
1
****
0 to 12000
5
A
0 to 2
1
---
5 to 6000
5
A
0 to 6
1
---
10 to 35000
1
0.1 xratio
40 to 600
1
V
40 to 600
1
V
50 to 60
10
Hz
0 to 3
1
---
0 to 59
1
---
See Analog Output Range Table on page 7–63
See Analog Output Range Table on page 7–63
0 to 59
1
---
See Analog Output Range Table on page 7–63
See Analog Output Range Table on page 7–63
1
---
0 to 59
1
---
See Analog Output Range Table on page 7–63
See Analog Output Range Table on page 7–63
0 to 59
1
---
See Analog Output Range Table on page 7–63
** Any valid Actual Values or Setpoints address.
**** Minimum Setpoint value represents "OFF".
FORMAT
FACTORY DEFAULT
F31
0 = NO
F31
0 = NO
F31
0 = NO
F31
0 = NO
F31
0 = NO
F47
0 = NONE
F1
0
F1
10 ms
F1
0 min.
F1
10.00 ¢
F1
0 min.
F1
10.00 ¢
F1
0 min.
F1
10.00 ¢
F1
100 A
F16
0 = OFF
F1
100 A
F15
0 = OFF
F1
1.0:1
F1
120 V
F1
600 V
F1
60 Hz
F44
0=A,B AND C
F14
0=NOT USED
0
0
F14
0=NOT USED
0
0
F2
0
F14
0=NOT USED
0
0
F14
0=NOT USED
0
GE Power Management