7.3 MODBUS MEMORY MAP
Table 7–10: PQM MEMORY MAP (Sheet 20 of 40)
GROUP
ADDR
(HEX)
WAVEFORM
07C0
CAPTURE
07C1
In
07C2
07C3
07C4
07C5
to
083E
083F
0840
0841
0842
to
0847
WAVEFORM
0848
CAPTURE
0849
Van
084A
084B
084C
084D
to
08C6
08C7
08C8
08C9
08CA
to
08CF
WAVEFORM
08D0
7
CAPTURE
08D1
Vbn
08D2
08D3
08D4
08D5
to
094E
094F
0950
0951
0952
to
0957
Notes:
* Data type depends on the Command Operation Code.
*** Maximum Setpoint value represents "OFF".
***** Maximum Setpoint value represents "UNLIMITED".
7-34
DESCRIPTION
In Waveform Capture Scale Factor (high)
In Waveform Capture Scale Factor (low)
In Sample Buffer 1
In Sample Buffer 2
In Sample Buffer 3
In Sample Buffer 4
In Sample Buffer 125
In Sample Buffer 126
In Sample Buffer 127
In Sample Buffer 128
Reserved
Reserved
Van Waveform Capture Scale Factor (high)
Van Waveform Capture Scale Factor (low)
Van Sample Buffer 1
Van Sample Buffer 2
Van Sample Buffer 3
Van Sample Buffer 4
Van Sample Buffer 125
Van Sample Buffer 126
Van Sample Buffer 127
Van Sample Buffer 128
Reserved
Reserved
Vbn Waveform Capture Scale Factor (high)
Vbn Waveform Capture Scale Factor (low)
Vbn Sample Buffer 1
Vbn Sample Buffer 2
Vbn Sample Buffer 3
Vbn Sample Buffer 4
Vbn Sample Buffer 125
Vbn Sample Buffer 126
Vbn Sample Buffer 127
Vbn Sample Buffer 128
Reserved
Reserved
PQM Power Quality Meter
7 MODBUS COMMUNICATIONS
RANGE
STEP
UNITS and
VALUE
SCALE
---
---
A x 10000
---
---
A x 10000
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
V x 10000
---
---
V x 10000
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
V x 10000
---
---
V x 10000
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
---
---
ADC counts
** Any valid Actual Values or Setpoints address.
**** Minimum Setpoint value represents "OFF".
FORMAT
FACTORY DEFAULT
F3
N/A
F3
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F3
N/A
F3
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F3
N/A
F3
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
F2
N/A
GE Power Management