GE Power Quality Meter Series Instruction Manual page 12

Table of Contents

Advertisement

1.1 INTRODUCTION
1
STATUS:
ALARM
- Alarm condition present
PROGRAM
- Setpoint programming is
enabled
SIMULATION
- Simulated values being
used for test/training
SELF TEST
- internal fault detected,
service required
g
PQM
Power Quality Meter
STATUS
ALARM
PROGRAM
SIMULATION
SELF TEST
CT INPUTS:
3 isolated phase CT inputs
1 isolated neutral CT input
1 Amp or 5 Amp secondary
VT INPUTS:
0-600V, 3 wire or 4 wire voltage inputs.
Direct (up to 600V) or VT (>600V for
isolation) connections.
1-2
COMMUNICATE:
For monitoring communication activity:
TX1
COM1 transmit data
RX1
COM1 receive data
TX2
COM2 transmit data
RX2
COM2 receive data
COMMUNICATE
RELAYS
TX1
ALARM
RX1
AUX1
TX2
AUX2
RX2
AUX3
AC/DC CONTROL POWER
Universal control power
90-300 VDC
70-265 VAC
GROUND:
Separate safety and filter ground
All inputs meet C37.90 and IEC 801-2
EMI, SWC, RFI interference immunity.
Figure 1–1: PQM FEATURE HIGLIGHTS
PQM Power Quality Meter
RELAYS:
ALARM
Alarm condition present.
See display for cause.
}
AUX1
Auxiliary relay activated by
AUX2
programmable function.
AUX3
ACTUAL
STORE
SETPOINT
RESET
MESSAGE
VALUE
1 OVERVIEW
DISPLAY
40 character illuminated display for
programming, monitoring, status, fault
diagnosis, user programmable messages
and setpoints. Programmable auto scan
sequence for unattended operation.
DOOR:
Door covers keys and computer port
when not in use.
KEYPAD:
Rubber keypad is dust tight and
splash proof.
SETPOINT KEY:
Program all setpoints. Tamperproof
settings with passcode and access jumper
prevent unauthorized setpoint changes.
COMPUTER INTERFACE:
RS232 comm port for connecting to a PC.
Use for downloading setpoints, monitoring,
data collection, printing reports.
ANALOG INPUT
823756AK.CDR
Accept 4-20mA analog inputs for transducer
interface.
ANALOG OUTPUTS
4 isolated 0-1mA or 4-20 mA outputs replace
8 transducers. Programmable including:
A, V, W, var, VA, Wh varh, PF, Hz
SWITCH INPUTS
}
A
Programmable for relay activation,
B
counters, logic, demand synchronization,
C
setpoint access, alarm position
D
4 OUTPUT RELAYS
}
ALARM
Programmable alarm conditions
AUX1
actuated by programmable
AUX2
setpoints, switch inputs, remote
AUX3
communication control.
COMMUNICATIONS
®
Dual RS485 comm ports Modbus protocol.
COM1
Continuous monitoring/control via
SCADA system rear (RS485).
COM2/3
Front (RS232) or rear (RS485) access
allows simultaneous communication
via a PC or for redundant comms.
PROGRAM UPDATING
Flash memory storage of firmware for field
updating via communications port. Enables
product updating on-site for latest features.
FUSE ACCESS
Control power fuse accessible under sliding
door.
COMPACT DESIGN
Panel mount replaces many discrete
components with one standard model.
823755AL.CDR
GE Power Management

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pqm seriesPqm-t20-c-a

Table of Contents