Number
Name
SW0120 to
PORT1 current error
SW0127
frame reception
status (each station)
(1)
SW0128 to
PORT1 current error
SW012F
frame reception
status (each station)
(2)
APPX
210
Appendix 4 Link Special Register (SW) List
Description
Stores the station number occurring a receive frame error line status caution level in
each station's PORT1.
• 0: A receive frame error line status caution level has not yet been occurred in each
station's PORT1.
• 1: A receive frame error line status caution level has been occurred in each station's
PORT1.
When Clear communication error count (SB0006) is turned ON, the stored status is
cleared.
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
16
15
14
13
12
11
SW0120
SW0121
32
31
30
29
28
27
SW0122
48
47
46
45
44
43
64
63
62
61
60
59
SW0123
80
79
78
77
76
75
SW0124
SW0125
96
95
94
93
92
91
SW0126
112
111
110
109
108
107
SW0127
Each number in the table represents a station No.
is fixed to 0.
(Conditions)
• This is enabled when the Baton pass status (own station) (SB0047) is OFF.
• Holds the data immediately before the error.
• This is enabled only for normal stations in the Baton pass status (each station)
(SW00A0 to SW00A7).
Stores the station number where a receive frame error line status warning level has
occurred in each station's PORT1.
• 0: A receive frame error line status warning level has not yet been occurred in each
station's PORT1.
• 1: A receive frame error line status warning level has been occurred in each
station's PORT1.
When Clear communication error count (SB0006) is turned ON, the stored status is
cleared.
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
16
15
14
13
12
11
SW0128
SW0129
32
31
30
29
28
27
SW012A
48
47
46
45
44
43
SW012B
64
63
62
61
60
59
80
79
78
77
76
75
SW012C
SW012D
96
95
94
93
92
91
112
111
110
109
108
107
SW012E
SW012F
Each number in the table represents a station No.
is fixed to 0.
(Conditions)
• This is enabled when the Baton pass status (own station) (SB0047) is OFF.
• Holds the data immediately before the error.
• This is enabled only for normal stations in the Baton pass status (each station)
(SW00A0 to SW00A7).
10
9
8
7
6
5
4
3
26
25
24
23
22
21
20
19
42
41
40
39
38
37
36
35
58
57
56
55
54
53
52
51
74
73
72
71
70
69
68
67
90
89
88
87
86
85
84
83
106
105
104
103
102
101
100
99
120
119
118
117
116
115
10
9
8
7
6
5
4
3
26
25
24
23
22
21
20
19
42
41
40
39
38
37
36
35
58
57
56
55
54
53
52
51
74
73
72
71
70
69
68
67
90
89
88
87
86
85
84
83
106
105
104
103
102
101
100
99
120
119
118
117
116
115
Availability
Master
station
2
1
18
17
34
33
50
49
66
65
82
81
98
97
114
113
2
1
18
17
34
33
50
49
66
65
82
81
98
97
114
113
Local
station

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec q80bd-j71gf11-t2Melsec q81bd-j71gf11-t2

Table of Contents