Routing parameters

Set communication paths for transient transmission between a station in the own network and stations in other networks.
Window
[View]  [Network Parameter]  "CC IE Field Number of Boards Setting" screen  [Routing Parameters] button
Operating procedure
1.
Set the items on the screen.
Item
Target Network No.
Relay Network No.
Relay Station No.
Condition Setting of Relay/Target
Network
[Clear] button
[Check] button
2.
Click the [End] button.
10 SETTING PARAMETERS
108
10.2 Setting Network Parameter
Description
Set the target network number. Numbers cannot be overlapped.
Setting range: 1 to 239
Set the first relay network number in the path to the target network.
Setting range: 1 to 239
Set the first relay station number in the path to the target network.
Setting range: 0 to 120
Set whether MELSECNET/10 network is to be used for routing the network.
Clears all settings.
Checks whether the settings are correct.