Mitsubishi Electric MELSEC SW1DNC-CCIEF-B User Manual page 107

Cc-link ie field network interface board
Table of Contents

Advertisement

Item
Event Condition
Word Device Setting Value
Channel No.
Event No.
[Clear] button
[Check] button
*1 When selecting "RECV Function", set "No Setting" for "RECV Function Reception Buffer" in the driver setting.
2.
Click the [End] button.
Combination of detection method and event condition
The following table shows results and events of the combination of detection method and event condition.
Device
Detection Method
RX
Edge Detect
RY
SB
Level Detect
RWw
Edge Detect
RWr
SW
Level Detect
RECV Function
Edge Detect
Description
Set the event condition. (Page 105 Combination of detection method and event condition)
Set the word device setting value.
DEC setting range: 0 to 65535
HEX setting range: 0000 to FFFF
Set the channel number (use for dedicated instructions) .
Setting range: 1 to 2
Set the event number.
Setting range: 0 to 15
Clears all settings.
Checks whether the settings are correct.
Event Condition
ON
OFF
ON
OFF
Equal
Unequal
Change
Equal
Unequal
Description
An event occurs at the rising edge of the device.
An event occurs at the falling edge of the device.
An event occurs by turning ON the device.
An event occurs by turning OFF the device.
An event occurs when values match. (First time only)
An event occurs when values do not match. (First time only)
An event occurs when values change. (First time only)
An event occurs when values match.
An event occurs when values do not match.
An event occurs when a specified channel receives data.
10 SETTING PARAMETERS
10.2 Setting Network Parameter