Configuration

The contact must be in the same control cabinet as the valve
block; restrict the maximum cable length to 2 m.
connection
Pluggable screw-type terminal*,
2-pole
cable cross-section (rigid or flexible)
0.14 mm²...1.5 mm² (AWG 28...16)
required switching
1.5 A / 24 V
capacity of the contact
*)
Upon delivery, the screw-type terminal is fitted with a bridge that
enables immediate operation of the electronic base module. Remove
the bridge before connecting a cable.
8.2.2 Diagnostics and reaction of electronic
base modules with EVS
If the valves are switched via EVS, the logic and display of the
electronic base module continue to run.
"EVS active" is shown on the display, the diagnostics "No valve
voltage / EVS active" (if activated) occurs via the backplane bus.
If there is no load voltage, the electronic base modules with EVS
react the same as those without EVS. The display is off and the
diagnostics "No supply voltage L+" (if activated) occurs.
If diagnostics messages for short circuit and wire break occurred
prior to shutdown via EVS, the messages remain. If a short circuit
or wire break occurred after shutdown via EVS, no diagnostics
will be generated.
Type 8647
9
confiGuraTion
The valve block can be used with all the interface modules of
SIMATIC ET 200SP and SIMATIC ET 200SP HA , except for the
interface module "IM 155-6 PN HS". There may be restrictions
when using older versions.
Some interface modules (e.g. "Basic" models) may have restric-
tions, e.g. with regard to the number of maximum usable
modules or the number of maximum available data bytes (for
details see product documentation of the interface modules).
The following interface modules can only be configured from the
firmware version stated below:
interface module
firmware version
IM 155-6 PN ST
3.0 or higher If necessary, execute
(6ES7 155-6AU00-0BN0)
IM 155-6 PN HF
2.2 or higher
(6ES7 155-6AU00-0CN0)
IM 155-6 PN HA
1.1 or higher
(6DL1155-6AU00-0PM0)
IM 155-6 DP HF
3.1 or higher "PQ8VS4EVS-5/3V"
(6ES7 155-6BU00-0CN0)
IM 155-6 DP HF
4.2 or higher
(6ES7 155-6BU01-0CN0)
The procedure for configuration is described in the operating
instructions for type 8647.
The operating instructions can be found online at
www.burkert.com
english
firmware update
according to the
manufacturer's
instructions
modules with GSD
are not adaptable