11.1
Manual activation of the valves
WarnIng
risk of injury due to actuators.
Unintentional system movements or states may result from
manual activation of the valves.
▶ Ensure that the movements of connected actuators cannot
cause injuries, damage or unwanted actions in the system.
CauTIon
risk of injury due to hot device components.
A longer duty cycle may result in the valves becoming hot.
▶ Only active manual override with a screwdriver.
Depending on the type of valve, valves can be activated man-
ually, e.g. for start-up or service tasks.
The valves can be manually activated even when the
valve block is not electrically powered.
→ Press (for key function) and rotate (for lock function) manual
override. Depending on the type of valve, it results in elec-
trical activation of the valve being canceled or limited.
→ Set manual overrides in neutral position after completing the
tasks.
28
english
Type 8647
Start-Ups
11.2
LED display connection units
The left-hand connection units feature the LED display
"PWR OK" for visual display of the operating state.
If the connection units are equipped with a pressure sensor
("PSU-..-PS"), they feature further LED displays:
- "DIAG" LED (red / green) for module status
- " Pressure" LED (red / yellow / green) for pressure status
(depends on the parameterized limit values)
LED "PWR OK"
(only for left-hand
connection units)
Fig. 15: LED displays of connection units
DIAG
PWR
OK
Pressure -
Error
Warn
Ok