Installation; Removing The Transportation Safety Device From The Valve Block - Burkert 8647 AirLINE SP Quick Start Manual

Valve block with interface to the distributed i/o system
Table of Contents

Advertisement

7

insTallaTion

WarnIng
risk of injury from improper assembly.
▶ Only trained technicians may perform assembly and disas-
sembly work.
▶ Perform installation work with suitable tools only.
CauTIon
risk of injury as a result of a heavy device falling.
A heavy device can fall down and cause injury during transport
or assembly work.
▶ Do not transport, install or remove heavy devices without
the aid of a second person and using suitable auxiliary
equipment.
The valve block is not connected securely to the standard rail
before the fastening screws are tightened.
▶ Make sure the valve block cannot fall down during the entire
installation process.
risk of injury due to sharp edges.
▶ Note that some valve terminal components may have sharp
edges.
Valve block AirLINE SP Type 8647 is supplied as a fully
assembled device. Any modifications should only be
carried out by Bürkert.
16
english
Type 8647
Installation
The valves are an exception to this rule and may be replaced
with identical valves by the user.
7.1
Removing the transportation safety
device from the valve block
The valve block is mounted on a standard rail for safe transpor-
tation. It must be removed from this standard rail for installation
in the control cabinet.
Fig. 7:
Releasing the valve block from the standard rail
→ Turn the fastening screws all the way counter-clockwise.
→ Tilt the valve block upward slightly and remove it from the
standard rail.
Fastening screws