System Start Up Time Characteristics
Symbol
Parameter
System Start-up Time
Wake-up from Condition where f
System Start-up Time
t
SST
Wake-up from Condition where f
System Speed Switch Time
FAST to SLOW Mode or
SLOW to FAST Mode
System Reset Delay Time
Reset Source from Power-on Reset or
LVR Hardware Reset
t
System Reset Delay Time
RSTD
LVRC/WDTC/RSTC Software Reset
System Reset Delay Time
Reset Source from WDT Overflow
t
Minimum Software Reset Width to Reset
SRESET
Note: 1. For the System Start-up time values, whether f
f
system oscillator. Details are provided in the System Operating Modes section.
SYS
2. The time units, shown by the symbols t
as provided in the frequency tables. For example t
3. If the LIRC is used as the system clock and if it is off when in the SLEEP Mode, then an additional LIRC
start up time, t
, as provided in the LIRC frequency table, must be added to the t
START
above.
4. The System Speed Switch Time is effectively the time taken for the newly activated oscillator to start up.
Rev. 1.00
High Voltage Touch A/D Flash MCU with HVIO
Test Conditions
V
Conditions
DD
—
f
=f
~f
/64, f
SYS
H
H
H
—
f
=f
=f
SYS
SUB
LXT
is Off
SYS
—
f
=f
=f
SYS
SUB
LIRC
—
f
=f
~f
/64, f
SYS
H
H
H
is On
—
f
=f
=f
or f
SYS
SYS
SUB
LIRC
—
f
switches from off → on
HIRC
—
f
switches from off → on
LXT
—
RR
=5V/ms
POR
—
—
—
—
—
—
is on or off depends upon the mode type and the chosen
SYS
, t
etc. are the inverse of the corresponding frequency values
HIRC
SYS
=1/f
, t
HIRC
HIRC
SYS
18
BS86DH12C
Min.
Typ.
Max.
=f
—
16
—
HIRC
—
1024
—
—
2
—
=f
—
2
—
HIRC
—
2
—
LXT
—
16
—
—
1024
—
30
48
72
10
16
24
45
90
180
=1/f
etc.
SYS
time in the table
SST
October 26, 2018
Ta=25°C
Unit
t
HIRC
t
LXT
t
LIRC
t
H
t
SUB
t
HIRC
t
LXT
ms
ms
μs
Need help?
Do you have a question about the BS86DH12C and is the answer not in the manual?
Questions and answers