3 Maintenance
3.3.8 Hoses
3.3.8 Hoses
General
This section describes maintenance on the hoses with the interval 500 hours.
Check hoses
xx0700000499
A
B
C
D
E
Continues on next page
118
DANGER
Turn off all electrical power, hydraulic and pneumatic pressure supplies before
entering the workspace of the manipulator.
Also read the safety sections:
•
Safety risks related to pneumatic/hydraulic systems on page 33
•
Risks associated with live electric parts on page 29
•
Safety risks during installation and service work on robots on page 23
Air filter inlet.
Ejector unit
Air filter inlet vacuum.
Swivel cup
Hose clamp
© Copyright 2008-2018 ABB. All rights reserved.