Default Values - Swann AMI Phosphate-II Operator's Manual

Version 5.01 and higher
Hide thumbs Also See for AMI Phosphate-II:
Table of Contents

Advertisement

AMI Phosphate-II

Default Values

11.
Alarm Relay
Signal Output
Relay 1/2
Installation:
Sensor:
Signal Output
1/2
90
Default Values
Hold after Cal.: .....................................................................300 Sec
...................................................................... same as in Installation
...................................................................... same as in Installation
...................................................................... same as in Installation
Clear Logger: ................................................................................no
Ref. Verification:.......................................................................0.235
Phosphate as:............................................................................PO4
Standard PO4: ..................................................................... 1.0 ppm
Meas. Interval: ....................................................................... 10 Min
Channels:........................................................................................1
Channel selection: ................................................................ internal
Cleaning:......................................................................... 2 Solutions
Parameter (SA 1: ..........................................................Phosphate 1
Parameter (SA 2: ......................................................... Sample Flow
Current loop: ......................................................................4-20 mA
Function: .................................................................................. linear
Scaling: Phosphate 1: Range low:.....................................0.00 ppm
Scaling: Phosphate 1. Range high: .................................10.00 ppm
Scaling: Sample flow: Range low: ............................................0 B/s
Scaling: Sample flow: Range high: .......................................200 B/s
Alarm high:.......................................................................10.00 ppm
Alarm low: ..........................................................................0.00 ppm
Hysteresis: .........................................................................0.10 ppm
Delay:.......................................................................................5 Sec
Sample Flow: Flow Alarm: .......................................................... yes
Sample Flow: Alarm High: ....................................................500 B/s
Sample Flow: Alarm Low: .......................................................10 B/s
Case temp. high:......................................................................65 °C
Case temp. low: .........................................................................0 °C
A-96.250.641 / 290312