Default Values - Swann AMI Hydrogen QED Operator's Manual

Table of Contents

Advertisement

AMI Hydrogen QED

Default Values

10.
Alarm Relay
Relay 1/2
Installation:
Signal Output 2
Alarm Relay:
74
Default Values
Hold after Cal.:......................................................................... 300 s
Mode: ................................................................................ Interval
Interval:.....................................................................................4 h
Delay ...................................................................................... 60 s
Signal Outputs........................................................................ hold
Output/Control ....................................................................... hold
...................................................................... same as in Installation
...................................................................... same as in Installation
Clear Logger: ................................................................................no
Miscellaneous; Offset:...........................................................0.0 ppb
Maintenance Interval ...................................................................3 h
Quality Assurance; Level: ........................................................ 0: Off
Parameter: ........................................................................ Hydrogen
Current loop: .....................................................................4 -20 mA
Function: .................................................................................. linear
Scaling: Range low: ............................................................0.00 ppb
Scaling: Range high:........................................................10.00 ppm
Parameter: ....................................................................Temperature
Current loop: .....................................................................4 -20 mA
Function: .................................................................................. linear
Scaling: Range low: ................................................................0.0 °C
Scaling: Range high:.............................................................50.0 °C
Alarm Hydrogen; Alarm high:...........................................10.00 ppm
Alarm Hydrogen; Alarm low: ...............................................0.00 ppb
Alarm Hydrogen; Hysteresis: ...............................................100 ppb
Alarm Hydrogen; Delay:............................................................... 5 s
If Flow = Q-Flow
Sample Flow, Flow Alarm: .......................................................... yes
Sample Flow, Alarm high: .................................................... 14.0 l/h
A-96.250.791 / 040219