EVAP TEMP SENSOR SHORTED (ACTIVE) —
TEST
3
Turn the ignition off.
Disconnect the ATC C1 harness connector.
Disconnect the in-line C202 harness connector.
Measure the resistance between the Evaporator Temperature Sensor Signal circuit
and the Sensor Ground circuit (IP side).
Is the resistance above 100k ohms?
Yes → Replace the Automatic Temperature Control (ATC) in accordance
→ Repair the Evaporator Temperature Sensor Signal circuit be-
No
ACTION
with the Service Information.
Perform BODY VERIFICATION TEST - VER 1.
tween the ATC C1 harness connector and the in-line C202
harness connector (IP side) for a short to Sensor Ground.
Perform BODY VERIFICATION TEST - VER 1.
Continued
525
HEATING & A/C
APPLICABILITY
All