R e p l a c i n g M a j o r C o m p o n e n t s
e) Disconnect the wiring from the two overflow detection probes and from the 3-position
connector from the drip tray detection switch.
f) Set aside the drip tray detection and overflow bracket – it will be required later.
g) Gently pull the door wiring harness out of the round cutout in the metal door frame/support on
the inside of the front door.
h) Remove the dispensing spout and hose assembly from the front door by lifting the spout off
the retaining bracket.
i) Remove the front door by lifting it up and off the door hinges.
3. Lay the front door flat down on a table, with the button side down.
NOTE: The front door must remain flat on a table until all the modifications are done. Lifting
the door will cause all of the switch caps and supporting components to fall to the
floor.
CAFFÈ MIO – OPERATION AND SERVICE
S E C T I O N
Disconnect
Drip Tray
Detection
Switch
5
R E P L A C I N G
Disconnect
Overflow
Detection
Probes
Spout
Retaining
Bracket
C O M P O N E N T S