Hydraulics
NOTE: See HYDRAULIC CONNECTION
SPECIFICATIONS on page 165 for correct
procedures for installing and tightening
hydraulic fittings and hoses.
Figure 86
4
REAR
3
NOTE: Mount the valve as shown with five hydraulic
ports facing the rear.
1. Place the hydraulic valve (1, Figure 86) onto the
mounting plate located just below the center fold
cylinders base ends.
2. Install four bolts with lock washers (2) and tighten.
3. Install and tighten the five straight fittings (3) on the
rear side of the hydraulic valve.
4. Install the 45° elbow fitting (4) on each side of the
hydraulic valve. Tighten fittings to the position shown.
1
4
2
B-17037
Assembly - High Speed Compact Disc
Figure 87
5. Install and tighten the six straight fittings (1, Figure
87) on the front side of the hydraulic valve.
Figure 88
3
1
4
1. Install the two 90° fittings (1, Figure 88) into the
hydraulic jack lock-up valve (2) and tighten as shown,
then install the valve between the mounts.
2. Install two 3/8" x 2-1/2" bolts (3) and 3/8" lock nuts (4)
and tighten.
1
FRONT
B-17038
1
2
B-17143
53