Warning And Error Messages - Sokkia X-1000 series Operator's Manual

Intelligence x-ellence station
Table of Contents

Advertisement

20.WARNING AND ERROR MESSAGES

The following is a list of the error messages displayed by the instrument and the meaning of each message. If
the same error message is repeated or if any message not shown below appears, the instrument has
malfunctioned. Contact your local dealer.
Backup battery dead. Clock display may no longer be correct.
The voltage supplied by the lithium battery either declines or is completely discharged.
Ask your local dealer to replace the battery for you.
Bad condition
The air is shimmering a lot, etc., measuring conditions are poor.
The center of the target cannot be sighted.
Resight the target.
Unsuitable distance measurement conditions when reflectorless measurement is set. When reflectorless
measurement is set, distance cannot be measured because the laser beam is striking at least two surfaces
at the same time.
Choose a single surface target for distance measurement.
Precautions for setting prism: "10. TARGET SIGHTING AND MEASUREMENT"
Calculation error
Coordinates identical to the known point coordinates observed during resection exist. Set another known
point so that the known point coordinates do not coincide.
During surface area calculation, conditions necessary for calculations are not met. Check conditions and try
again.
An error occurred during calculation.
Checking Device... Please wait several minutes to start the connected.
Cellular communication is not ready.
After powering ON, it is necessary to wait about 5 minutes until cellular communication is ready. Wait about
5 minutes and then perform a connection.
Error: Instrument info.
Error: Self check
Press [OK] to cancel the message. If this error message appears frequently, contact your local dealer.
Failed Change Carrier!
During cellular communication, carrier cannot be changed as desired.
Check the settings and try again.
Failed Device Power On/Off! (218)
Inside Device Power cannot be turned ON/OFF.
Try again.
Incorrect password.
Input password does not match set password.
Input correct password.
Input over 3 letters!
The input password consists of less than 3 characters. Input a password at least 3 characters in length.