Sokkia X-1000 series Operator's Manual page 83

Intelligence x-ellence station
Table of Contents

Advertisement

7. Press [CALC] or [YES] to automatically start
calculations after observations of all known points
are completed. Instrument station coordinates,
station elevation, and standard deviation, which
describes the measurement accuracy, are
displayed.
• "Occ. Elev" is not displayed when the result is
calculated only by angle measurements.
• In auto measurement, the result is automatically
displayed when the measurement is completed.
Standard deviation for the northing, easting and
elevation coordinates of each point are displayed
by pressing [DETAIL].
8. If there are problems with the results of a point,
align the cursor with that point and press [OMIT].
"OMIT" is displayed to the right of the point.
Repeat for all results that include problems.
9. Press [RE_CALC] to perform calculation again
without the point designated in step 8. The result
is displayed.
If there are no problems with the result, go to step
10.
If problems with the result occur again, perform the
resection measurement from step 4.
• Press [RE OBS] to measure the point designated
in step 8.
If no points are designated in step 8, all the points
or only the final point can be observed again.
79
14. RESECTION MEASUREMENT