Sokkia X-1000 series Operator's Manual page 167

Intelligence x-ellence station
Table of Contents

Advertisement

Power Supply
Power source
Working duration at 20 °C
BDC70:
BDC60A (external battery, optional accessory) + BDC70:
BDC61A (external battery, optional accessory) + BDC70:
Battery state indicator
Auto power-off
External power source
Battery (BDC70)
Nominal voltage:
Capacity:
Dimensions:
Weight:
Charger (CDC68A)
Input voltage:
Charging time per battery (at 25°C):
BDC70:
Charging temperature range: 0 to 40°C
Storage temperature range:-20 to 65°C
Size:
Weight:
*30: Figures will change depending on the operating environment including temperatures and observation
conditions.
*31: Figures when using the instrument with both an external battery and a standard battery mounted.
General
Operating system
Display
Backlight:
Touch panel:
Keyboard
Trigger key
Sensitivity of levels
Circular level (on base plate):
Circular level (for main unit) (optional accessory):
Electronic Circular levels:
Optical plummet
Magnification:
Field of view:
Image:
Minimum focus:
Circular level:
Rechargeable Li-ion battery BDC70
*30
about 4hours
about 9 hours
about 14 hours
4 levels
5 levels (5/10/15/30 min/Not set) (selectable)
6.7 to 12V
7.2V
5,240mAh
40 (W) x 70 (D) x 40 (H) mm
about 197g
100 to 240VAC
about 5.5 hours (Charging can take longer than the times stated above
when temperatures are either especially high or low.)
94 (W) X 102 (D) X 36 (H) mm
about 170g
Windows Embedded Compact 7
4.3 inch Transmissive TFT VWGA color LCD
LED: 9 brightness levels (0 to 8) (selectable)
Resistance-sensitive analog type
24 keys
Key backlight:Yes
Yes (right side)
10'/2 mm
8'/2 mm
Graphic display range: 6' (inner circle)
Digital display range:±6' 30"
3X
Erect
0.5 m
10'/2 mm
*31
*31
163
26. SPECIFICATIONS

Advertisement

Table of Contents
loading

Table of Contents