19.3 Observation Conditions - Reflector (Target)

Select "Obs.condition" in <Configuration> and select "Reflector".
Factory setting
Factory settings are indicated in the above <Reflector>.
• "Prism+" indicates a target used with an external device or in a program installed in the Program mode.
prism constant correction value
Reflective prisms each have their prism constant.
Set the prism constant correction value of the reflective prism you are using. When selecting "N-Prism" in
"Reflector", prism constant correction value is set to "0" automatically.