27.EXPLANATIONS
27.1 High Accuracy with the 360° Prism
Sighting can be more accurately performed by facing the 360
Prism toward the instrument. The 360
Prism
°
°
should be set up so that a pair of diametrically-opposed hexagonal points on its rubber flanges are aligned with
the sighting direction of the instrument (see the diagram below).
: Hexagonal points
When using the ATP1SII, the 360
Prism should be set up so that a pair of diametrically-opposed marks on top
°
of the prism are aligned with the sighting direction of the instrument.
: Prism sighting direction
165