Mini pole prism OR1PA:
Compact prism CP01:
Standard prism AP01AR X 1:
Reflective sheet RS90N-K:
Reflective sheet RS50N-K:
Reflective sheet RS10N-K:
Reflectorless (White):
*3
Prism (tracking)
Reflective sheet target (tracking)
Reflectorless (White) (tracking)
Minimum display
Fine measurement:
Rapid measurement:
Tracking measurement/Road measurement:
Maximum slope distance display (Except for tracking)
Distance unit
Accuracy (D: measurement distance; Unit: mm) (Under normal atmospheric conditions
(ISO 17123-4: 2001)
(Using prism or using 360° Prism ATP1/ATP1S
iX-1000 series
Fine measurement: (1.0 + 2 ppm X D) mm
Rapid measurement: (5 + 2 ppm X D) mm
iX-500 series
Fine measurement: (2.0 + 2 ppm X D) mm
Rapid measurement: (5 + 2 ppm X D) mm
(Using reflective sheet target)
Fine measurement: (2 + 2 ppm X D) mm
Rapid measurement: (5 + 2 ppm X D) mm
(Reflectorless (White))
Fine measurement:
Rapid measurement:
Measurement mode
Measuring time
Fine measurement:
Rapid measurement:
Tracking measurement:
Atmospheric correction
Temperature input range:
Pressure input range:
1.3 to 500 m (1,640 ft)
1.3 to 2,500 m (8,200 ft)
iX-1000 series: 1.3 to 6,000 m (19,680 ft)
iX-500 series: 1.3 to 4,000 m (13,120 ft)
1.3 to 500 m (1,640 ft)
1.3 to 300 m (980 ft)
1.3 to 100 m (320 ft)
iX-1000 series: 0.3 to 800 m (2,620 ft)
iX-500 series: 0.3 to 600 m (1,960 ft)
:1.3 to 1,000 m (3,280 ft)
*4
:1.3 to 350 m (1,140 ft)
*5
:0.3 to 300 m (980 ft)
0.0001m (0.001 ft/ 1/16 inch)/0.001 m (0.005 ft/ 1/8 inch)
0.0001m (0.001 ft/ 1/16 inch)/0.001 m (0.005 ft/ 1/8 inch)
0.001 m (0.005 ft/ 1/8 inch)/0.01 m (0.1ft/ 1/2 inch)
9,600.000 m (31,490 ft) (using prism or reflective sheet target)
1,200.000 m (3,930 ft) (Reflectorless)
m/ft/inch (selectable)
*4
*5
(2 + 2ppm X D) mm (0.3 to 200 m)
(5 + 10ppm X D) mm (over 200 to 350 m)
(10 + 10ppm X D) mm (over 350 to 1,000 m)
(6 + 2ppm X D) mm (0.3 to 200 m)
(8 + 10ppm X D) mm (over 200 to 350 m)
(15 + 10ppm X D) mm (over 350 to 1,000 m)
Fine measurement (single/repeat/average)/Rapid measurement
(single/repeat)/Tracking (selectable)
(fastest time under good atmospheric conditions
EDM ALC at appropriate setting, slope distance)
less than 1.5 sec + every 0.9 sec or less
less than 1.3 sec + every 0.6 sec or less
less than 1.3 sec + every 0.4 sec or less
- 35 to 60°C (in 0.1°C step)/ - 22 to 140°F (in 0.1°F step)
500 to 1,400 hPa (in 0.1hPa step)
375 to 1,050mmHg (in 0.1mmHg step)
14.8 to 41.3inchHg (in 0.01inchHg step)
*7
*7
*4
*4
*4
*3
)
*8
159