Motor error EXXX
A problem has occurred with the motor drive and operation stops.
Power the instrument OFF then ON to correct the problem.
If this error message appears frequently, contact your local dealer.
Need base pt. obs
During REM measurement, the observation of the target was not completed normally.
Reset and sight the prism and perform measurement again.
New password Diff.
During new password setting, the passwords input twice are different.
Input new password twice correctly.
No solution
The calculation of the instrument station coordinates during resection does not converge.
Access the results and if necessary, perform the observations again.
Out of range
During gradient % display, the display range (less than ± 1000%) has been exceeded.
During REM measurement, either the vertical angle has exceeded horizontal ±89
is greater than 9999.999m.
Install the instrument station far from the target.
Reflectorless not supported!!
Auto Tracking cannot be performed in reflectorless mode.
Use the prism to carry out automatic sighting.
Remote Control communication err!!
Communication between the Remote controller for Remote Control System and the instrument failed.
Check the status (communications setup, power supply, cable connections etc.) of the Remote controller,
wireless modem and cables.
Sheet not supported!!
Auto Tracking cannot be performed with the sheet.
Use the prism to carry out automatic sighting.
Signal off
The reflected light is not observed when distance measurement begins. Or, during measurement, the
reflected light has weakened or is blocked.
Either sight the target again or, when using a reflective prism, increase the number of reflective prisms.
SIM card Error!
SIM card is not inserted or not inserted correctly.
Check if the SIM card is inserted correctly.
Start Up Error: Step XX
Press [OK] to close the message. If the same error message is repeated, contact your local dealer.
Take BS reading
The origin measurement is not finished normally in missing line measurement. Collimate the origin
accurately and measure it again.