Check AP300 LED Activity

Figure 14: Hoffman Bracket ACC-AP300-BHE
6. Using a Phillips screw driver, attach the bracket using the two supplied 6-32 3/16 SEMS screws.
7. Flip the assembly over and mount into the Hoffman enclosure, attach the Ethernet cable to the
AP300 rotating the assembly to place the Ethernet cable within the enclosure.
8. Using a Phillips screw driver, tighten the four bracket screws to the enclosure.
9. Adjust the antennas as needed.
Check AP300 LED Activity
When AP300 first connects to the co ntroller (and any time the access point is rebooted), the AP initial-
izes and is then programmed by the controller. When the AP first powers up, all LEDs are green.
Figure 15: AP300 Status LEDs
After the AP300 is connected, check the status of the LEDs. The functions of the five LEDs are described
below.
34
Meru Access Point Installation Guide
S
L
R
R
P
T
A
F
F
W
A
N
1
2
R
T
© 2010 Meru Networks, Inc.