802.3At Usage; Installation Requirements; Additional Equipment - Meru Networks AP300 Installation Manual

Hide thumbs Also See for AP300:
Table of Contents

Advertisement

Installation Requirements

802.3at Usage

When using System Director 3.6/4.0 and 802.3at, the following radio combinations are recommended:
Single 3x3 radio
Dual 2 x 2 radios
Dual radio with one set to 2x2 and the other one set to 3x3
Dual 3x3 radios are recommended with a limitation. Use 802.3at power for two 3x3 MIMO radios
when the switch has a high enough power output to support all devices on the PoE. Calculate the
amount of power needed by each AP300/AP320i in 3x3 mode (13 watts), add that to power required
by other PoE devices on the switch and compare that value to the total power output from the
switch. The calculation for 802.3at PoE use looks something like this:
(Number of AP300s * 13watts) + (sum of all other PoE devices power requirements) <= switch
power provided
Installation Requirements
.
Installation Type
Horizontal mounting
Vertical mounting over a wall
stud
Vertical mounting on sheetrock
Horizontal mounting below a
hanging ceiling
Reusing an existing bracket from
another AP

Additional Equipment

A power source is needed to power the AP300. See
an AP320i to the ceiling or wall, you need a small key like the ones used to lock suitcases.
40
Meru Access Point Installation Guide
Order These Additional Items
None
None
None
None
For connection to Meru AP200 or AP150 only, order shoulder screws,
Meru part number 665-00012 (SCR, PIC.1/4*1/8 10-32 SKT SHLDR
SCR 303 STNLS). Connection to other brackets does not require this.
Determine Power
Requirements. If you want to lock
© 2010 Meru Networks, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ap300iAp1000Ap200Ap150Oap180

Table of Contents