Figure 111: Diagnostics > Ping Test; Table 107: Ping Test - Allied Telesis IS230-10GP Web User Manual

Industrial ethernet layer 2 switch
Hide thumbs Also See for IS230-10GP:
Table of Contents

Advertisement

To access this page, click Diagnostics > Ping Test.
The following table describes the items in Figure 111.
Item
Description
IP Address
Enter the IP address or host name of the station to ping. The initial
value is blank. The IP Address or host name you enter is not retained
across a power cycle. Host names are composed of series of labels
concatenated with periods. Each label must be between 1 and 63
characters long, maximum of 64 characters.
Count
Enter the number of echo requests to send. The default value is 4.
The value ranges from 1 to 5. The count entered is not retained
across a power cycle.
Interval (in sec)
Enter the interval between ping packets in seconds. The default value
is 1. The value ranges from 1 to 5. The interval entered is not retained
across a power cycle.
Size (in bytes)
Enter the size of ping packet. The default value is 56. The value
ranges from 8 to 5120. The size entered is not retained across a
power cycle.
Ping Results
Display the reply format of ping.
PING 172.17.8.254 (172.17.8.254): 56 data bytes
--- 172.17.8.254 ping statistics ---
4 packets transmitted, 0 packets received, 100% packet loss
Or
PING 172.17.8.93 (172.17.8.93): 56 data bytes
64 bytes from 172.17.8.93: icmp_seq=0 ttl=128 time=0.0 ms
64 bytes from 172.17.8.93: icmp_seq=1 ttl=128 time=0.0 ms
64 bytes from 172.17.8.93: icmp_seq=2 ttl=128 time=0.0 ms
64 bytes from 172.17.8.93: icmp_seq=3 ttl=128 time=0.0 ms
--- 172.17.8.93 ping statistics ---
4 packets transmitted, 4 packets received, 0% packet loss
round-trip min/avg/max = 0.0/0.0/0.0 ms
Apply
Click Apply to display ping result for the IP address.
IS230-10GP Industrial layer 2 Switch Web User Guide
Figure 111. Diagnostics > Ping Test
Table 107. Ping Test
125