Allied Telesis AR415S Installation And Safety Manual

Ar400 series
Hide thumbs Also See for AR415S:
Table of Contents

Advertisement

AR400 Series Router
Installation and Safety Guide
AR415S
AR440S
AR441S
AR442S
AR450S

Advertisement

Table of Contents
loading

Summary of Contents for Allied Telesis AR415S

  • Page 1 AR400 Series Router Installation and Safety Guide AR415S AR440S AR441S AR442S AR450S...
  • Page 2 AR400 Series Router Installation and Safety Guide AR415S AR440S AR441S AR442S AR450S...
  • Page 3 Allied Telesis has been advised of, known, or should have known, the possibility of such damages.
  • Page 4: Table Of Contents

    Package Contents ........................4 AR415S Router ........................6 Installing the AR415S .......................6 Configuring the AR415S ....................9 Connecting Data Cables to AR415S ................. 13 System LEDs on AR415S ..................... 14 AR440S, AR441S, AR442S Routers .................. 15 Installing the AR440S, AR441S, AR442S ..............15 Configuring the AR440S, AR441S, AR442S ............
  • Page 5: Models Covered By This Guide

    You can download updates to this document from www.alliedtelesis.com/support/documentation/ Package Contents Before beginning any installation, please check the package contents. Contact your authorised Allied Telesis distributor or reseller if any items are damaged or missing. AR415S one AR400 Series router ■...
  • Page 6 AR400 Series Router Documentation and Tools CD-ROM (includes the complete ■ AR400 Series Document Set and utilities) one warranty card ■ To install your router, see: “AR415S Router” on page 6 ■ “AR440S, AR441S, AR442S Routers” on page ■ “AR450S Router” on page 27 ■...
  • Page 7: Ar415S Router

    AR400 Series Router AR415S Router This section describes how to install the AR415S router. “Installing the AR415S” below ■ “Configuring the AR415S” on page 9 ■ “Connecting Data Cables to AR415S” on page 13 ■ “System LEDs on AR415S” on page 14 ■...
  • Page 8 Installing the Router in a Rack 1. Gather additional items. You will need: • the rack-mount kit (in your router package, or ordered from your authorised Allied Telesis distributor or reseller) • a Phillips #1 screwdriver • screws and cage nuts to attach the brackets to your rack 2.
  • Page 9 AR400 Series Router 6. Mount the router in the rack. Use appropriate rack mounting screws (not supplied). Applying Power to the Router 1. Check the supply voltage and the router’s rated voltage. AR400 Series routers are fitted with a universal mains power supply that will function over the range 100 VAC to 240 VAC and 50 Hz to 60 Hz.
  • Page 10: Configuring The Ar415S

    CLI or the GUI to complete the configuration. “Using the CLI to configure the AR415S” below ■ “Using the GUI to configure the AR415S” on page 11 ■ Using the CLI to configure the AR415S This section describes how to access the router’s command line interface (CLI) using a terminal or PC connected to the router’s console port.
  • Page 11 AR400 Series Router 2. Log in and set the password. The login prompt appears on the terminal or PC. If the login prompt does not appear, press [Enter] two or three times. When the router boots for the first time it automatically creates an account with manager privileges.
  • Page 12 This section describes how to access the GUI via a switch port in VLAN1 on the AR415S router, when the PC and the router are in the same subnet, in order to configure the router. The router’s switch ports all belong to VLAN1 by default.
  • Page 13 AR400 Series Router 3. Enable IP. In the CLI, enter the command: enable ip 4. Assign an IP address to VLAN1. Assign the VLAN1 interface an IP address in the subnet that the PC uses, using the command: add ip interface=vlan1 ip=ipaddress mask=mask 5.
  • Page 14: Connecting Data Cables To Ar415S

    Installation and Safety Guide Connecting Data Cables to AR415S Connecting the router to your network: 1. Connect to the LAN If you have not already done so, use straight-through Ethernet patch cables to connect the device(s) on your private network (LAN) to the router’s switch port(s).
  • Page 15: System Leds On Ar415S

    AR400 Series Router System LEDs on AR415S The LEDs described in the following table show the operational status and port activity for the AR415S router. State Function Green The router is receiving power and the power switch is ON. Amber Lit briefly during router start up, or the router is malfunctioning.
  • Page 16: Ar440S, Ar441S, Ar442S Routers

    “Connecting Data Cables to AR440S, AR441S, AR442S” on page 25 ■ “System LEDs on AR440S, AR441S, AR442S” on page 26 ■ For corresponding information about installing an AR415S, see “AR415S Router” on page For corresponding information about installing an AR450S, see “AR450S Router”...
  • Page 17 Installing the Router in a Rack 1. Gather additional items. You will need: • the rack-mount kit (in your router package, or ordered from your authorised Allied Telesis distributor or reseller) • a Phillips #1 screwdriver • screws and cage nuts to attach the brackets to your rack 2.
  • Page 18 Installing the Router on a Wall You can install the router on a firm wall. 1. Gather additional items. You will need: • a wall mount bracket kit (ordered from your authorised Allied Telesis distributor or reseller) • a Phillips #1 screwdriver •...
  • Page 19 AR400 Series Router Applying Power to the Router 1. Check the supply voltage and the router’s rated voltage. AR400 Series routers are fitted with a universal mains power supply that will function over the range 100 VAC to 240 VAC and 50 Hz to 60 Hz. For continued protection against the risk of fire and shock hazard, replace fuses only with the same type and rating.
  • Page 20: Configuring The Ar440S, Ar441S, Ar442S

    Installation and Safety Guide Configuring the AR440S, AR441S, AR442S By default, the DHCP server on the router is enabled, and all the switch ports belong to the default VLAN (vlan1), which has an IP address of 192.168.1.1 (“Default Configuration on AR440S, AR441S, AR442S” on page 35).
  • Page 21 AR400 Series Router 1. Connect the PC to a router switch port. The PC can be connected directly, or through your LAN. To connect the PC directly to the router, use a straight-through Ethernet cable to connect an Ethernet card on the PC to any one of the router’s switch ports. See the following figure.
  • Page 22 Installation and Safety Guide 2. Set PC to automatic IP address. Set the PC to accept an IP address assigned to it by the router’s DHCP server. In Windows XP: From the Start menu, select Control Panel > Network and Internet Connections >...
  • Page 23 AR400 Series Router 5. Configure the router. You can configure the router using the GUI wizards or menu. Important To ensure configuration settings are saved correctly, use the GUI menus and buttons to navigate, not your browser’s buttons. Caution As a security precaution, change the password as soon as possible.
  • Page 24 Installation and Safety Guide Using the CLI to configure the router This section describes how to access the CLI via a switch port in VLAN1 on the AR440S, AR441S and AR442S routers, when the PC and the router are in the same subnet, in order to configure the router.
  • Page 25 AR400 Series Router 2. Log in and set the password. The login prompt appears on the terminal or PC. If the login prompt does not appear, press [Enter] two or three times. When the router boots for the first time it automatically creates an account with manager privileges.
  • Page 26: Connecting Data Cables To Ar440S, Ar441S, Ar442S

    Installation and Safety Guide Connecting Data Cables to AR440S, AR441S, AR442S Connecting the router to your network: 1. Connect to the LAN If you have not already done so, use straight-through Ethernet patch cables to connect the device(s) on your private network (LAN) to the router’s switch port(s).
  • Page 27: System Leds On Ar440S, Ar441S, Ar442S

    AR400 Series Router System LEDs on AR440S, AR441S, AR442S The LEDs described in the following table show the operational status and port activity for the AR440S, AR441S and AR442S routers. State Function Power Green The router is receiving power and the power switch is ON.
  • Page 28: Ar450S Router

    “Connecting Data Cables to the AR450S” on page 33 ■ “System LEDs on the AR450S” on page 34 ■ For corresponding information about installing an AR415S, see “AR415S Router” on page For corresponding information about installing an AR440S, AR441S or AR442S, see “AR440S, AR441S, AR442S Routers”...
  • Page 29 AR400 Series Router Installing the Router in a Rack 4. Gather additional items. You will need: • the rack-mount kit included in the router package • a Phillips #1 screwdriver • screws and cage nuts to attach the brackets to your rack 5.
  • Page 30: Configuring The Ar450S

    Installation and Safety Guide 3. Connect the provided power cord to the AC power inlet and clip it in place. Switch the router’s power switch to the ON position. The Power LED lights continuously and the System LED lights briefly. The Port LEDs also light briefly. The router is supplied with an approved power cord that incorporates a moulded plug.
  • Page 31 AR400 Series Router 2. Log in and set the password. The login prompt appears on the terminal or PC. If the login prompt does not appear, press [Enter] two or three times. When the router boots for the first time it automatically creates an account with manager privileges.
  • Page 32 Installation and Safety Guide Using the GUI to configure the AR450S This section describes how to access the GUI via a switch port in VLAN1 on the AR450S router, when the PC and the router are in the same subnet, in order to configure the router.
  • Page 33 AR400 Series Router 3. Enable IP. In the CLI, enter the command: enable ip 4. Assign an IP address to VLAN1. Assign the VLAN1 interface an IP address in the subnet that the PC uses, using the command: add ip interface=vlan1 ip=ipaddress mask=mask 5.
  • Page 34: Connecting Data Cables To The Ar450S

    Installation and Safety Guide Connecting Data Cables to the AR450S Connecting the router to your network: 1. Connect to the LAN. If you have not already done so, use straight-through Ethernet patch cables to connect the device(s) on your private network (LAN) to the router’s switch port(s).
  • Page 35: System Leds On The Ar450S

    AR400 Series Router System LEDs on the AR450S The LEDs described in the following table show the operational status and port activity for AR450S routers. State Function Power Green The router is receiving power and the power switch is System Red or Lit briefly during router start up, or the router is Amber...
  • Page 36: Default Configuration On Ar440S, Ar441S, Ar442S

    # Enable DNS relay, so that DNS will work for DHCP clients. enable ip dnsrelay The AR415S and the AR450S boot.cfg files have no significant default configurations. 613-000313 Rev D...
  • Page 37: Documentation And Tools Cd-Rom

    AR400 Series Router Documentation and Tools CD-ROM The Documentation and Tools CD-ROM bundled with each router contains the complete Document Set for your router. The CD-ROM also includes tools for managing your router. The Document Set on the CD-ROM includes: this Installation and Safety Guide ■...
  • Page 38: Connection To Mains Voltage Supply

    Installation and Safety Guide Connection to mains voltage supply This router is supplied with a power cord has been approved for use and incorporates a moulded plug. It must only be used with the power cord supplied. For continued protection against the risk of fire and shock hazard, replace fuses only with the same type and rating.
  • Page 39 AR400 Series Router Connection to ISDN network This product is supplied with an approved patch cord for connection to the ISDN Basic Rate Network. Ports for the connection of other apparatus The following interfaces normally operate at Safe Extra Low Voltage (SELV) levels: asynchronous (console) ports ■...
  • Page 40: Safety

    CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling. OPERATING TEMPERATURE: AR415S, AR450S: This product is designed for a maximum ambient temperature of 40 degrees C. AR440S, AR441S, AR442S: This product is designed for a maximum ambient temperature of 50 degrees C.
  • Page 41: Sicherheit

    Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen zum Kühlen freien Zugang zur Raumluft haben. BETRIEBSTEMPERATUR: AR415S, AR450S: Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 40 °C entworfen. AR440S, AR441S, AR442S: Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 50 °C entworfen.
  • Page 42: Sikkerhed

    ADVARSEL: Ventilationsåbninger må ikke blokeres og skal have fri adgang til den omgivende luft i rummet for afkøling. BETJENINGSTEMPERATUR: AR415S, AR450S: Dette apparat er konstrueret til en omgivende temperatur på maksimum 40 grader C. AR440S, AR441S, AR442S: Dette apparat er konstrueret til en omgivende temperatur på...
  • Page 43: Veiligheid

    OPGELET: De ventilatiegaten mogen niet worden gesperd en moeten de omgevingslucht ongehinderd toelaten voor afkoeling. BEDRIJFSTEMPERATUUR: AR415S, AR450S: De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius. AR440S, AR441S, AR442S: De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 50 graden Celsius.
  • Page 44: Sécurité

    ATTENTION: Ne pas bloquer les fentes d’aération, ceci empêcherait l’air ambiant de circuler librement pour le refroidissement. TEMPÉRATURE DE FONCTIONNEMENT: AR415S, AR450S: Ce matériel est capable de tolérer une température ambiante maximum de ou 40 degrés Celsius. AR440S, AR441S, AR442S: Ce matériel est capable de tolérer une température ambiante maximum de ou 50 degrés Celsius.
  • Page 45: Turvallisuus

    HUOMAUTUS: Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi. KÄYTTÖLÄMPÖTILA: AR415S, AR450S: Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 40 °C. AR440S, AR441S, AR442S: Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 50 °C.
  • Page 46: Norme Di Sicurezza

    ATTENZIONE: le prese d’aria non vanno ostruite e devono consentire il libero ricircolo dell’aria ambiente per il raffreddamento. TEMPERATURA DI FUNZIONAMENTO: AR415S, AR450S: Questo prodotto è concepito per una temperatura ambientale massima di 40 gradi centigradi.
  • Page 47: Sikkerhet

    FORSIKTIG: Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med romtemperatur for avkjøling. DRIFTSTEMPERATUR: AR415S, AR450S: Dette produktet er konstruert for bruk i maksimum romtemperatur på 40 grader celsius. AR440S, AR441S, AR442S: Dette produktet er konstruert for bruk i maksimum romtemperatur på...
  • Page 48: Segurança

    CUIDADO: As aberturas de ventilação não devem ser bloqueadas e devem ter acesso livre ao ar ambiente para arrefecimento adequado do aparelho. TEMPERATURA DE FUNCIONAMENTO: AR415S, AR450S: Este produto foi projetado para uma temperatura ambiente máxima de 40 graus centígrados.
  • Page 49: Seguridad

    TEMPERATURA REQUERIDA PARA LA OPERACIÓN: AR415S, AR450S: Este producto está diseñado para una temperatura ambiental máxima de 40 grados C. AR440S, AR441S, AR442S: Este producto está diseñado para una temperatura ambiental máxima de 50 grados C.
  • Page 50: Säkerhet

    VARNING: Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande rumsluft för avsvalning. DRIFTSTEMPERATUR: AR415S, AR450S: Denna produkt är konstruerad för rumstemperatur ej överstigande 40 grader Celsius. AR440S, AR441S, AR442S: Denna produkt är konstruerad för rumstemperatur ej överstigande 50 grader Celsius.
  • Page 51: Us Federal Communications Commission (Fcc)

    USOC Jack Type For the AR440S and AR442S routers USOC Jack Type RJ11C Should you experience trouble with this telephone equipment, please contact: ALLIED TELESIS INC. 19800 NORTH CREEK PARKWAY #200 BOTHELL WASHINGTON 98011 TEL: 425 487 8880 FAX: 425 489 9191 If trouble is experienced with this equipment (AR021U PIC, AR440S, AR442S), for repair or warranty information, please contact the above.
  • Page 52: Canadian Department Of Communications

    Installation and Safety Guide Canadian Department of Communications The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction.
  • Page 53: Emission Compliance Statements

    AR400 Series Router Emission Compliance Statements STANDARDS: The AR415S, AR440S, AR441S, and AR442S meet the following standards: Category Approval Agency and Requirement Safety UL60950-1 EN60950-1 AS/NZS 60950 Electromagnetic Compliance FCC CFR47 Part 15 Class A EN55022 Class A VCCI Class A...
  • Page 54 Installation and Safety Guide STANDARDS: The AR450S meets the following standards: Category Approval Agency and Requirement Safety UL60950 EN60950 AS/NZS 3260 Electromagnetic Compliance FCC CFR47 Part 15 Class B EN55022 Class B VCCI Class B AS/NZS CISPR22 Class B Immunity EN55024 U.S.

This manual is also suitable for:

Ar442sAr441sAr450sAr440s

Table of Contents