A.3: Central Unit Rack - Honeywell H-S81-HS Operation Manual

Industrial fire panel
Hide thumbs Also See for H-S81-HS:
Table of Contents

Advertisement

Central Unit Rack
A.3 Central Unit Rack
Part Number
S81-CU001-1
S81-U1002-1
S81-E2003-1
S81-U1006-1
S81-T8004-1
S81-T8001-1
S81-T8007-1
S81-T8002-1
S81-U0000-1
S81-F0000-1
S81-CFT20/05
S81-CFT10/2
S81-CFT14/2
EDS-205
A.4 I/O Rack
Part Number
S81-EU001-1
S81-E2001-1
S81-E2001-2
S81-E2002-1
A.5 I/O Modules
Part Number
S81-F3002-1
S81-F3002-2
S81-F4001-1
S81-F4001-2
S81-F4002-1
S81-F4002-2
S81-F4003-1
S81-F4003-2
S81-F5001-1
S81-F5001-2
S81-F5002-1
S81-F5003-1
S81-F5004-1
S81-F5004-2
S81-F6001-1
S81-F6002-1
S81-F7002-1
S81-F7006-1
S81-F7007-1
S81-F7008-1
S81-F7009-1
S81-F7010-1
H-S81-HS Installation & Operation Manual — P/N LS10114-000HI-E:A 2/24/2015
Description
Central unit
Central processing unit
Two slot bus for central unit
Operator interface unit
Default I/O module
16-terminal termination module.
16-relay termination module.
RS232/Current loop converter module
Blank panel for central unit
Blank panel
Flat cable for termination module
Flat cable for serial connection
Flat cable for S81-T8004-1 module connection
24VDC MOXA Ethernet Switch
Description
Expansion rack
13 slot bus for flat cable termination
13 slot bus for multi-conductor cable termination
Controller rack module
Description
8 monitored input module
8 monitored input module
Module with 1 x 4-20mA analog input
Module with 1 x 4-20mA analog input
Module with 2 x 4-20mA analog input
Module with 2 x 4-20mA analog input
Module with 8 x 4-20mA analog input
Module with 8 x 4-20mA analog input
Module with 8 x 500mA monitored outputs
Module with 8 x 500mA monitored outputs
Module with 16 x 250mA non monitored outputs
Module with 8 x 250mA monitored
Module with 4 x 2A monitored outputs for solenoids
Module with 4 x 2A monitored outputs for solenoids
Fire extinguishing module
Logic module
Loop control module for ESP addressable devices
Modbus RTU Master/Slave module
Control module for Honeywell bus
Control module for scales
Control module for Apollo bus
Control module for System Sensor bus
Notes
with 19 inch 3 unit aluminum slot
Used only in systems with single CPU
5 centimeter long
2 meter long
2 meter long
5 x 10/100BaseT ports
Notes
with 19 inch 3 unit aluminum slot
I/O module redundancy not allowed
I/O module redundancy allowed
Notes
Redundancy not possible
Redundancy possible
Redundancy not possible
Redundancy possible
Redundancy not possible
Redundancy possible
Redundancy not possible
Redundancy possible
Redundancy not possible
Redundancy possible
Redundancy not possible
Redundancy not possible
Redundancy not possible
Redundancy possible
Redundancy possible
Redundancy possible
Redundancy not possible
Redundancy not possible
Redundancy not possible
Redundancy not possible
Redundancy not possible
Redundancy not possible
Parts List
161

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents