Pressing 1 while viewing the Print Screen allows the user to print the History file which will detail all of the system activities since the
file was last cleared from memory.
Pressing 2 while viewing the Print Screen allows the user to print the Walktest log which will detail all of the system activations during
walktest since the log was last cleared. Refer to "Walktest" on page 92 for additional information on the display.
Pressing 3 while viewing the Print Screen will exit the Print operation.
4.19.9 ANN-BUS
READ STATUS
1=HISTORY
2=PRINTER
3=ANN-BUS
Read Status Screen #3
ANN-BUS Screen #1 indicates whether the ANN-BUS is enabled (Yes/No).
Pressing 1 while viewing ANN-BUS Screen #1 will display BUS Module addresses 1-8 and the devices, if any, located at those
addresses.
Pressing 2 while viewing ANN-BUS Screen #1 will display the printer settings for the printer connected to the FACP. This information
includes:
Serial or Parallel printer
Printer Supervision (Yes or No)
Off-line Timer setting
Baud Rate
Data Bits
Parity
Stop Bits
Pressing 1 while viewing ANN-BUS Screen #2 will display the programmed options for the ANN-80 devices connected to the ANN-
BUS. These include Piezo enable/disable, Lock enable/disable and which buttons/keys on the annunciator are enabled/disabled.
Pressing 2 while viewing ANN-BUS Screen #2 will display the zone programming for each ANN-RLY relay.
Pressing 3 while viewing ANN-BUS Screen #2 will display the zone, if any, that has been assigned as the All-Call Zone.
4.19.10 Central Station
READ STATUS
1=CENTRAL STATION
2=PHONE LINES
3=SERVICE TERMINAL
Read Status Screen #4
Central Station Screen #1 indicates whether the Central Station Reporting is enabled or disabled and if the Reports will be sent to one or
both the Primary and Secondary Central Station phone numbers. Central Station Screen #2 provides information on the Primary and Sec-
ondary Central Station programming which includes:
Test Time Interval
Account Code
24 Hour Test Time
Phone Number
Communication Format
Event Codes
This screen also displays the Call Limit for each unique DACT trouble call within a 24 hour period
4.19.11 Phone Line
Pressing 1 while viewing Read Status Screen #4 will display the following screen:
The second and third lines of this screen indicate that both the Primary and Secondary phone lines have been configured for touchtone
dialing operation.
104
Pressing 3 while viewing Read Status Screen #3 will display the settings for the ANN-BUS options as
shown in the following screens:
ANN-BUS
BUS ENABLED
1=BUS MODULES
2=ANN-S/PG OPTIONS
ANN-BUS Screen #1
Pressing 1 while viewing Read Status Screen #4 will display the following screens:
CENTRAL STATION
REPORTING
REPORT STYLE
Central Station Screen #1
PHONE LINES
PRIMARY
SECONDARY
3=SUPERV PHONE LINE
1=ANN-80 OPTIONS
NO
2=ANN-RLY OPTION
3=ANN-AUDIO OPTIONS
CENTRAL STATION
1=PRIMARY
YES
BOTH
2=SECONDARY
3=CALL LIMIT
TCH TNE
TCH TNE
MS-5UD & MS-10UD Series Manual — P/N 52626:C7 6/12/2018
ANN-BUS
ANN-BUS Screen #2
0
Central Station Screen #2
Read Status

Advertisement

Table of Contents
loading

Table of Contents