I/O modules

Standard Connection Diagrams

Supported devices
This module can control the following types of Apollo addressable devices:
Part Number
Description
55000-600
XP95 Optical smoke detector
55000-500
XP95 Ionization smoke detector
55000-268 /273
XP95 Reflective Beam
55000-885
XP95 Multi-sensor detector
55000-400
XP95 Heat detector (Standard)
55000-401
XP95 Heat detector (High Temperature)
55100-905
XP95 Manual Call Point
XPA-CB-12034-APO
XPander Optical smoke detector
XPA-CB-11170-APO
XPander Heat detector (Standard)
XPA-CB-11171-APO
XPander Heat detector (High Temperature)
XPA-CB-13032-APO
XPander Multi-sensor detector
XPA-IN-14011-APO
XPander Input/Output Unit
XPA-MC-14006-APO
XPander Manual Call Point
XPA-CB-14003-APO
XPander Sounder/Beacon & Sounder Base
XPA-IN-14007-APO
XPander Loop Interface
55000-640
XP95 I.S. Optical smoke detector
55000-540
XP95 I.S. Ionization smoke detector
55000-440
XP95 I.S. Heat detector (Standard)
55100-940
XP95 I.S. Manual Call Point
55000-847
Standard Input/Output Unit
55000-875
Standard Mains Input/Output Unit
55000-843
Standard Switch Monitor
55000-841
Standard Switch Monitor Plus
55000-845
Standard Zone Monitor
55000-852
Standard Sounder Control Unit
55000-803
Din Rail Input/Output Unit
55000-797
Din Rail Main Input/Output Unit
55000-822
Din Rail Switch Monitor
55000-821
Din Rail Switch Monitor Plus
55000-760
Din Rail mini Switch Monitor
55000-812
Din Rail Zone Monitor
55000-182
Din Rail Sounder Control Unit
55000-773MAR
Marine Din Rail Zone Monitor
55000-772MAR
Marine Din Rail Switch Monitor Plus
55000-181MAR
Marine Din Rail Sounder Control Unit
58000-600MAR
Discovery Marine Optical smoke detector
H-S81-HS Installation & Operation Manual — P/N LS10114-000HI-E:A 2/24/2015
Figure 2.40 Loop Standard Connection Diagram
Parts of the H-S81-HS System
Type Pros-81 Notes
X-OSD
Powered by the loop
X-ISD
Powered by the loop
X-RB
Powered by the loop
X-HSM
Powered by the loop
X-HD
Powered by the loop
X-HHD
Powered by the loop
X-MCP
Powered by the loop
P-OSD
Powered by the loop
P-HD
Powered by the loop
P-HHD
Powered by the loop
P-HSM
Powered by the loop
P-IOU
Powered by the loop
P-MCP
Powered by the loop
P-SB
Powered by the loop
P-LI
Powered by the loop
X-OSD
Powered by the loop
X-ISD
Powered by the loop
X-HD
Powered by the loop
X-MCP
Powered by the loop
X-IOU
Powered by the loop
X-MIO
Powered by the loop
X-SM
Powered by the loop
X-SMP
Powered by the loop
X-ZMU
Powered by the loop
X-SCU
Requires external power supply
X-IOU
Powered by the loop
X-MIO
Powered by the loop
X-SM
Powered by the loop
X-SMP
Powered by the loop
X-MSM
Powered by the loop
X-ZMU
Powered by the loop
X-SCU
Requires external power supply
X-ZMU
Powered by the loop
X-SMP
Powered by the loop
X-SCU
Requires external power supply
D-OSD
Powered by the loop