l Preventive maintenance programs to be performed every three years
of machine use or whenever a process count of about 180,000 is
reached (
)
Reference
Maintenance program
section
2.1
Checking Error Log
3
Checking the Image/
Conveyance
4
Pulling Out the Machine
5.4
Removing the Covers
(3 Year Intervals)
5.5
Removing the Covers
(3 Year Intervals : #50001 or
later)
6
Turning OFF the High-Voltage
Switch
7.3
Replacing the IP Suction
Pumps (#50001 or Later)
8
Checking the Feed/Load
Conveyor Unit
8.4.1
Cleaning the Brush Roller
8.4.2
Cleaning the Brush Roller
9
Checking the Side-Positioning
Conveyor Unit
9.3.3
Replacing the Cleaning Guide
11.10
Reinstalling the Side-
Positioning Conveyor Unit
13.1
Removing the Lamp Assembly -
14
Checking Lamp Assembly
14.1
Cleaning/Replacing the Lamps -
14.3
Replacing the Filter
14.5
Replacing the Lamp Assembly
14.6
Reinstalling the Lamp
Assembly
16
Turning ON the High-Voltage
Switch
17
Cleaning/Reinstalling the
Covers and Louvers
18
Cleaning/Replacing the Air
Filter
011-202-08E
09.30.2009 FM5540
Periodic
Time
replacement
Remarks
requirements
parts
1
15
1
4
#20001 or later
2
#50001 or later
1
15
Pump (x4)
#50001 or later *1
4
-
#20001 or later
-
#50001 or later
10
Guide (x2)
2
10
#20001 or later
-
Filter (x1)
#20001 or later
-
#50001 or later
-
1
4
3
#20001 or later
19
Securing the Machine
20
Checking the Image/
Conveyance
21
Checking the Laser
Performance/ Sensitivity
22
Checking Error Log
24
Reset the number that the
pumps are used
*1: Replace the IP suction pumps when either one of the following conditions is met.
- Every three years
- When process count reaches the number set in CONDITION OF PUMP LIFE
under EDIT CONFIGURATION.
When CONDITION OF PUMP LIFE is set to "NO DISP", 180,000 process
counts is the condition. In other cases, the set number of the process count is
the condition.
l Parts to be replaced every three years of machine use or whenever a
process count of about 180,000 is reached
Reference
Parts Name
Parts No.
section
7.3
Pump
133Y2034
9.3.3
Guide
363Y0460
363Y0461
14.3
Filter
603Y0066
14.5
Lamp case
840Y100201
(Lamp
Assembly)
CR-IR 363 Service Manual
1
15
1
1
Qty.
Remarks
4
Pump
1
Side-positioning conveyor unit (surface side)
1
Side-positioning conveyor unit (back side)
1
Erasure filter
1
Lamp case (Lamp Assembly)
PM-4
PM-4

Advertisement