Omron SYSMAC C Series Operation Manual page 209

Analog i/o units
Hide thumbs Also See for SYSMAC C Series:
Table of Contents

Advertisement

DM Memory Coding Sheets
C500-DA501 Analog Output Unit
Output Signal Range Settings
Output
p
point
i
0 to 10 V
1
2
3
4
5
6
7
8
Output Signal Range Setting DIP Switch (on the Back of the Unit)
Settings
DIP
s
switch
c
pin No.
0 to 10 V
1
4
ON
2
5
ON
3
6
OFF
198
Enter circles in applicable cells.
Output signal range
0 to 5 V
–5 to 5 V
Output signal range
0 to 5 V
–5 to 5 V
ON
ON
ON
OFF
ON
ON
DIP Switches for Setting Voltage Output Ranges (on
the Front of the Unit)
DIP
Voltage output
switch
pin No.
4
–10 to 10 V
3
–5 to 5 V
2
0 to 10 V
1
0 to 5 V
Note 1. When a voltage output is set, set the same output signal range on the out-
put signal range DIP switch and the voltage output range DIP switch.
2. Outputs will not be correct if more than one DIP switch pin is turned ON.
Turn ON only one of the pins shown above.
3. When the output signal range is set to 4 to 20 mA or to 0 to 20 mA, the
output will not be affected by the settings of these DIP switch pins.
–10 to 10 V
0 to 20 mA
–10 to 10 V
0 to 20 mA
ON
OFF
OFF
ON
OFF
OFF
ON
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Appendix A
Factory
setting
i
4 to 20 mA
0 to 10 V
Factory set-
ting
4 to 20 mA
0 to 10 V
OFF
ON
ON
ON
ON
OFF
OFF
Factory setting
OFF
OFF
ON
ON
y