5. Diagnostics and error handling
5.2

Error characteristics

No. Fault messages
02
Channel fault short circuit 24V
02
Module error short circuit 0 V on cycle
output T1357
03
Channel fault, wire break
05
Module fault, undervoltage
29
Channel fault, configuration, e.g. invalid
function mode
55
Channel fault, process value
61
Module fault, overvoltage
65
Module fault F_DEST_ADD, differing
results
5-4
The input module distinguishes between types of error and
responds accordingly with:
Channel passivation if a failure can be allocated to pre­
cisely that channel (e.g. with cross-circuiting detection).
Module passivation if the fault that occurs cannot be al­
located precisely to one channel and no component de­
fect is detected (e.g. communication failure with
PROFIsafe).
Safe shut-down if a single microcontroller detects the
failure of a component that is required to run the pro­
gram.
Passivation as a result of the incorrect setting of a func­
tion mode.
The input module can only transmit certain error messages as
a function of the selected function mode.
Function mode
0
ü
ü
ü
ü
1
2
3
4
5
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
Festo P.BE-CPX-F8DE-P-E N en 1610a English
6
7
8
9
10
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü

Advertisement

Table of Contents
loading

Table of Contents