Festo CPX-F8DE-P Manual page 65

Input module terminal cpx
Hide thumbs Also See for CPX-F8DE-P:
Table of Contents

Advertisement

1. System overview CPX-F8DE-P
Festo P.BE-CPX-F8DE-P-E N en 1610a English
Only use sensors with antivalent outputs on which one
contact opens before the other contact closes.
Ensure that the NO and/or NC switch on sensors with the
appropriate clock signal connections for the channel pair
are connected up è Circuit diagram.
Note
Safety-related evaluation only with the following connec­
tion blocks:
– CPX-M-AB-4-M12X2-5POL-T
– CPX-AB-8-KL-4POL.
Functional safety
PL e, Cat. 4 / SIL 3
with 2 switches/sensors, wiring and safety function in
accordance with EN 574 type IIIC.
Function mode 8 – 1oo2 T (equivalent, with clock
signal monitoring, robust)
Signal evaluation of mechanical contacts on a two-channel
switch/sensor (internal equivalent) or of 2 independent, tried
and tested switches.
Circuit diagram
Tab. 1/23: Function mode 8 – 1oo2 T (robust)
Channel pair ports
T0
T2
T4
E1
E3
E5
0 V
E0
E2
E4
T1
T3
T5
T6
E7
E6
T7
1-33