Light Curtain - Festo CPX-F8DE-P Manual

Input module terminal cpx
Hide thumbs Also See for CPX-F8DE-P:
Table of Contents

Advertisement

1. System overview CPX-F8DE-P

1.4.4 Light curtain

Mode 5
E1
0 V
E0
24 V
FE
Fig. 1/7: Connection of a light grid
1-46
This sample application shows the connection of transmitter
and receiver of a light grid via a channel pair on the input
module.
OSSD2
OSSD1
Channel pair Mode
E0/E1
Depending on the connection block used, the permitted cur­
rent consumption per connection may vary:
CPX-M-AB-4-M12X2-5POL
CPX-M-AB-4-M12X2-5POL-T up to 0.7 A.
When wiring in a switch cabinet, the input module can also be
operated with connection block CPX­AB­8­KL­4POL. All sig­
nals are available there without any restriction.
24 V
Comment
5
Signal evaluation of a sensor
(typically OSSD)
up to 2 A
Festo P.BE-CPX-F8DE-P-E N en 1610a English
0 V
FE

Advertisement

Table of Contents
loading

Table of Contents