3. Commissioning
Module parameter: DIL switch setting
Function no.
4828 + m * 64 + 22
4828 + m * 64 + 23
Description
Indicates the switch setting of the PROFIsafe address selector switch on the
input module.
In addition to the PROFISsafe parameter F_Dest_Add (è Chapter 3.6) the setting
of the address selector switch can be interrogated by CPX parameters for
diagnostic purposes – e.g. with the operator unit (read only).
Bit
Low byte (4828 + m * 64 + 22)
Bit 0:
Bit 1:
...
Bit 7:
High byte 4828 + m * 64 + 23)
Bit 0:
Bit 1:
Bit 2 ... 7: reserved or 0
Values
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
SW 7 SW 6 SW 5 SW 4 SW 3 SW 2 SW 1 SW 0 Lowbyte
0
0: switch element is OFF
1: switch element is ON
Comment
This parameter can only be changed by changing the DIL switch setting (read
only).
Tab. 3/5:
DIL switch setting
3-10
m = module number (0 ... 47)
SW 0
SW 1
SW 7
SW 8
SW 9
0
0
0
0
Operator unit
[PROFIsafe Addr]
0
SW 9 SW 8 high byte
[0]
[1]
Festo P.BE-CPX-F8DE-P-E N en 1610a English