Festo CPX-F8DE-P Manual page 59

Input module terminal cpx
Hide thumbs Also See for CPX-F8DE-P:
Table of Contents

Advertisement

1. System overview CPX-F8DE-P
Festo P.BE-CPX-F8DE-P-E N en 1610a English
up to PL e, Cat. 3 / SIL 3
with certified sensor and appropriate safety category
and with wiring monitoring through the connected sensor
(example B).
Function mode 4 – 1oo1 D (antivalent)
Signal evaluation of up to 2 independent two-channel
switches/sensors (NO or NC) or up to 4 operationally tried
and tested switches per channel pair.
For E1, E3, E5 and E7, the clock signals are wired as a mirror
image of E0, E2, E4 and E6
Circuit diagrams
Tab. 1/18: Function mode 4 – 1oo1 D
This function mode tests the switch function and wiring of the
sensors.
Only use sensors with antivalent outputs on which one
contact opens before the other contact closes.
Channel pair ports
T0
T2
T4
E1
E3
E5
0 V
E0
E2
E4
T1
T3
T5
T0
T2
T4
E1
E3
E5
0 V
E0
E2
E4
T1
T3
T5
T6
E7
E6
T7
T6
E7
E6
T7
1-27