Table 9-2
System Performance, Corrected, 75Ω, T/R Calibration
Directivity
Source Match:
Reflection (One-Port Cal)
Transmission (Enhanced Response Cal) 41
Transmission (Response Cal)
Load Match
Reflection Tracking
Transmission Tracking:
Enhanced Response Cal
Response Cal
a. Option 1E1 adds a 60 dB step attenuator to the HP 8712ET/8714ET.
b. These specifications apply for measurements made using "fine" bandwidth,
Specifications
HP 8712ET/8714ET (75 Ω) with Attenuator Option 1E1
HP 85036B/E (Type-N, 75 Ω) Cal Kit, T/R Calibration
Description
no averaging, and at an environmental temperature of 25° ± 5° C, with less
than 1° C deviation from the calibration temperature.
9-8
a
b
Specification
(in dB)
300 kHz
1.3 GHz
to 1.3 GHz
to 3 GHz
48
43
41
35
35
21
15
18
15
±
±
0.021
0.02
±
±
0.04
0.062
±
±
0.125
0.295