CH1 Factory default setting
This area restores the offset/gain setting value in user range setting. For details, refer to the following.
Page 168 CH1 User range setting
CH1 User range setting
This area restores the offset/gain setting value in user range setting.
■Buffer memory address
The following shows the buffer memory address of this area.
• For the R60DA4
Buffer memory name
CH Factory default setting offset value
CH Factory default setting gain value
CH User range setting offset value
CH User range setting gain value
CH Factory default setting offset value (When
the Q compatible mode function is used)
CH Factory default setting gain value (When
the Q compatible mode function is used)
CH User range setting offset value (When the
Q compatible mode function is used)
CH User range settings gain value (When the
Q compatible mode function is used)
• For the R60DAV8 and R60DAI8
Buffer memory name
CH Factory default setting offset value
CH Factory default setting gain value
CH User range setting offset value
CH User range setting gain value
CH Factory default setting offset value (When
the Q compatible mode function is used)
CH Factory default setting gain value (When
the Q compatible mode function is used)
CH User range setting offset value (When the
Q compatible mode function is used)
CH User range settings gain value (When the
Q compatible mode function is used)
When the following operations are performed, the data to be used is stored (saved).
• Writing the initial setting by engineering tool
• Turning off and on Operating condition setting request (Y9) (Data is not saved when the mode is switched from the normal
mode to the offset/gain setting mode by the mode switching setting.)
• Writing an offset/gain value in the offset/gain setting mode (When User range write request (YA) is turned off and on)
When restoring the offset/gain setting value in user range setting, set the same data as the saved data in this area to the
corresponding area of the D/A converter module that is the restoration destination.
For the offset/gain setting, refer to the following.
 MELSEC iQ-R Digital-Analog Converter Module User's Manual (Startup)
■Default value
The default value is 0 for all channels.
APPENDICES
168
Appendix 3 Buffer Memory
CH1
CH2
4004
4006
4005
4007
4012
4014
4013
4015
202
204
203
205
210
212
211
213
CH1
CH2
CH3
4004
4006
4008
4005
4007
4009
4020
4022
4024
4021
4023
4025
202
204
206
203
205
207
218
220
222
219
221
223
CH3
4008
4009
4016
4017
206
207
214
215
CH4
CH5
CH6
4010
4012
4014
4011
4013
4015
4026
4028
4030
4027
4029
4031
208
210
212
209
211
213
224
226
228
225
227
229
CH4
4010
4011
4018
4019
208
209
216
217
CH7
CH8
4016
4018
4017
4019
4032
4034
4033
4035
214
216
215
217
230
232
231
233