CH1 Alert output upper limit value
Set the range of digital values to output alerts.
For the alert output function, refer to the following.
Page 28 Alert Output Function
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Alert output upper limit value
CH Alert output upper limit value (When the Q
compatible mode function is used)
■Setting range
The setting range is from -32768 to 32767. In the channel where a set value does not satisfy the condition "alert output upper
limit value > alert output lower limit value", an alert output upper/lower limit value inversion error (error code: 1B1H) occurs.
When 'CH1 Alert output setting' (Un\G508) is set to Disable (1), the setting of 'CH1 Alert output upper limit value' (Un\G510) is
ignored.
■Enabling the setting
Turn on and off 'Operating condition setting request' (Y9) to enable the setting.
■Default value
The default value is 0 for all channels.
■Precautions
When the shift function is used, always set a value in consideration of 'CH1 Input value shift amount' (Un\G480).
CH1 Alert output lower limit value
Set the range of digital values to output alerts.
For the alert output function, refer to the following.
Page 28 Alert Output Function
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Alert output lower limit value
CH Alert output lower limit value (When the Q
compatible mode function is used)
■Setting range
The setting range is from -32768 to 32767. In the channel where a set value does not satisfy the condition "alert output upper
limit value > alert output lower limit value", an alert output upper/lower limit value inversion error (error code: 1B1H) occurs.
When 'CH1 Alert output setting' (Un\G508) is set to Disable (1), the setting of 'CH1 Alert output lower limit value' (Un\G512) is
ignored.
■Enabling the setting
Turn on and off 'Operating condition setting request' (Y9) to enable the setting.
■Default value
The default value is 0 for all channels.
■Precautions
When the shift function is used, always set a value in consideration of 'CH1 Input value shift amount' (Un\G480).
CH1
CH2
CH3
510
710
910
86
88
90
CH1
CH2
CH3
512
712
912
87
89
91
CH4
CH5
CH6
1110
1310
1510
92
94
96
CH4
CH5
CH6
1112
1312
1512
93
95
97
Appendix 3 Buffer Memory
CH7
CH8
1710
1910
98
100
A
CH7
CH8
1712
1912
99
101
APPENDICES
157

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60dav8R60da4R60dai8

Table of Contents