CH1 Wave pattern data points setting
This area is for setting the data points of the wave pattern to be output when the wave output function is used.
The setting for this area is enabled only in the wave output mode. In other modes, changing the setting value is ignored.
In the channel where the set values in this area and in 'CH1 Wave pattern data points setting' (Un\G528, Un\G529) satisfy the
following conditions, a wave data registry area range error (error code: 1D9H) occurs and 'Error flag' (XF) turns on. The
wave output does not start.
(Wave pattern start address setting + Wave pattern data points setting - 1) > 89999 (the last buffer memory address of the
wave data registry area)
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Wave pattern data points setting
CH Wave pattern data points setting (When the
Q compatible mode function is used)
■Setting range
The setting range is from 1 to 80000 (the number of data points of the wave data registry area).
In the channel where a value out of the setting range is set, a wave pattern data points setting range error (error code:
1D5H) occurs and 'Error flag' (XF) turns on. The wave output does not start.
However, when the value of 'CH1 Wave pattern start address setting' (Un\G526, Un\G527) is out of the setting range, the
above error does not occur.
■Enabling the setting
Turn on and off 'Operating condition setting request' (Y9) to enable the setting.
■Default value
The default value is 0 for all channels.
CH1 Wave pattern output repetition setting
This area is for setting the number of wave pattern outputs when the wave output function is used.
The setting for this area is enabled only in the wave output mode. In other modes, changing the setting value is ignored.
Setting value
-1
1 to 32767
In the channel where a value out of the setting range is set, a wave pattern output repetition setting range error (error code:
1D6H) occurs and 'Error flag' (XF) turns on. The wave output does not start.
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Wave pattern output repetition setting
CH Wave pattern output repetition setting
(When the Q compatible mode function is used)
■Enabling the setting
Turn on and off 'Operating condition setting request' (Y9) to enable the setting.
■Default value
The default value is 1 (time) for all channels.
APPENDICES
162
Appendix 3 Buffer Memory
CH1
CH2
CH3
528
728
928
529
729
929
1040
1042
1044
Description
The wave pattern is output in analog unlimitedly.
The wave pattern is output in analog for the set number.
CH1
CH2
CH3
530
730
930
1056
1057
1058
CH4
CH5
CH6
1128
1328
1528
1129
1329
1529
1046
1048
1050
CH4
CH5
CH6
1130
1330
1530
1059
1060
1061
CH7
CH8
1728
1928
1729
1929
1052
1054
CH7
CH8
1730
1930
1062
1063