CH1 Constant for wave output conversion cycle
This area is for setting the constant to determine the conversion cycle (specifying a multiple of the conversion speed) for each
channel when the wave output function is used.
The setting for this area is enabled only in the wave output mode. In other modes, changing the setting value is ignored.
The conversion cycle of each channel is determined from the combination of the reference conversion speed (80s), number
of channels where D/A conversion is enabled, and the constant for wave output conversion cycle.
• "Conversion cycle" = "Reference conversion speed (80s)  "Number of channels where D/A conversion is enabled" 
"Constant for wave output conversion cycle"
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Constant for wave output conversion cycle
CH Constant for wave output conversion cycle
(When the Q compatible mode function is used)
■Setting range
The setting range is from 1 to 5000.
In the channel where a value out of the setting range is set, a wave output conversion cycle setting range error (error code:
1D7H) occurs and 'Error flag' (XF) turns on. The wave output does not start.
■Enabling the setting
Turn on and off 'Operating condition setting request' (Y9) to enable the setting.
■Default value
The default value is 1 for all channels.
CH1
CH2
CH3
531
731
931
1064
1065
1066
CH4
CH5
CH6
1131
1331
1531
1067
1068
1069