nstallation procedure for quick-fit connectors
inverter could cause serious damage to the unit and lead to invalidation of the warranty.
tion to polarity.
2
4...6mm
5.5...7.5mm
- Weidmüller PV-Stick
- Weidmüller WM4
- MultiContact MC4
- Amphenol H4.
Please refer to the document "String inverters – Product manual ap-
pendix" available at www.abb.com/solarinverters for information on the
The model of connectors installed on your inverter must be matched by
the same model of the respective corresponding parts to be used (che-
cking the conforming corresponding part on the manufacturer's website
or with ABB).
Installation of Weidmüller PV-Stick connectors does not require any spe-
cial tooling.
- Strip the cable to which you want to apply the connector (after verifying
that it complies with the connector limits).
- Insert the wire into the connector until you hear a locking "click".
Click !
- Tighten the knurled ring nut for optimal clamping.
- 89 -
5 - Installation
-
-
3 ... 4 Nm
0 !